Overview
Glorene and 8th Rereg
BMP Registration
Approved

10/01/2025 to 09/30/2035 (10 years)
23 credits
23 credits (100%)

Yes
No
No

Registration Area & BMPs
Declarations
Credit Schedule
10/1/2025
10 years
09/30/2035
This is a re-registration of Glorene and 8th for another 10 year term (2026-2035). Though the project was completed in 2004 and the lifespan of project improvements is assumed to be 20 years, BMP RAM scores indicate that the four stormwater BMPs in this project are still functioning at a high level. Additionally, the City is committed to continuing maintenance of all the basins as needed to maintain the current level of performance.

100%
23
23
PLRM Models and Load Reduction
Glorene_and_8th (Project7)
ExpectedRoads (Scenario2) Baseline Scenario 20%
ExpectedConditions (Scenario3) Expected Scenario 20%

6,402.6 21.8 75.6 N/A
1,699.8 7.2 29.8 N/A
Load Reduction 4,702.8 14.6 45.8 23
Treatment BMPs
Yes

Dry Basin G8-DryBasin1 1,999.8 6 18 10 Essential No
Dry Basin G8-DryBasin2 960 3.6 12.2 5 Key No
Infiltration Basin G8-InfiltrationBasin2 763 3.2 12.2 4 Key No
Infiltration Basin G8-InfiltrationBasin1 490.6 1.4 4.4 2 Supporting No
Total 21

No distributed BMPs added to registration

The City plans to maintain treatment BMPs within CSLTB11 based on BMP RAM and NPDES inspections. Dry Basins are considered Essential BMPs and will be maintained by the City Street Maintenance crew on an As-Needed basis. Maintenance will be performed by backhoe and/or hand crew to remove excess sediment from the basin. Emphasis will be placed on restoring the soil to an infiltration rate consistent with the BMP RAM benchmark value. Infiltration Basins (one Essential and one Key BMP) will be maintained in a similar fashion to Dry Basins.
The City plans to inspect all treatment BMPs with CSLTB11 in accordance with the BMP RAM. Additional inspections may be performed if required by NPDES permits, or to assess performance or maintenance needs. Inspections will take place beginning in spring and will continue through the fall. Dry Basins, which are essential BMPs, will be inspected according to the BMP RAM and NPDES permit. Public Works staff will use the Constant Head Permeameter (CHP) to determine the infiltration rate of the basin. Staff will also perform a visual inspection and record results with a GIS application on a field tablet computer. Infiltration Basins will be inspected in a similar fashion. Inspections of all Basins will take place in the late spring or early summer.
None
Parcel BMPs
No
Single Family Residential
7% 0%
109.2 7.64 0 7.0% 0.0% 262.7
109.2 7.64 0 7.0% 0.0% 356.9
Multi-Family Residential
19% 0%
21.1 4.01 0 19.0% 0.0% 420.3
21.1 4.01 0 19.0% 0.0% 463.3
Commercial, Industrial, and Community Use
5% 0%
24.3 1.22 0 5.0% 0.0% 9020.7
24.3 1.21 0 5.0% 0.0% 9020.7
Other Pollutant Control Strategies

No other pollutant control strategies implemented in this registration